authorDon Brady <[email protected]>2024-02-08 10:19:52 -0700
committerTony Hutter <[email protected]>2024-04-29 13:50:05 -0700
commitc1c26a77ff38770b80ed1c97aea867d3ad9bf6ee (patch)
tree694326890ff3acb5e4fc2b7122f438a9e02429ce /lib/libzfs/libzfs_pool.c
parentdb65272aef3d380d2bd1c94907826f2b9ec9205e (diff)
Add slow disk diagnosis to ZED
Slow disk response times can be indicative of a failing drive. ZFS currently tracks slow I/Os (slower than zio_slow_io_ms) and generates events (ereport.fs.zfs.delay). However, no action is taken by ZED, like is done for checksum or I/O errors. This change adds slow disk diagnosis to ZED which is opt-in using new VDEV properties: VDEV_PROP_SLOW_IO_N VDEV_PROP_SLOW_IO_T If multiple VDEVs in a pool are undergoing slow I/Os, then it skips the zpool_vdev_degrade(). Sponsored-By: OpenDrives Inc. Sponsored-By: Klara Inc. Reviewed-by: Tony Hutter <[email protected]> Reviewed-by: Allan Jude <[email protected]> Reviewed-by: Brian Behlendorf <[email protected]> Co-authored-by: Rob Wing <[email protected]> Signed-off-by: Don Brady <[email protected]> Closes #15469
Diffstat (limited to 'lib/libzfs/libzfs_pool.c')
-rw-r--r--lib/libzfs/libzfs_pool.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/lib/libzfs/libzfs_pool.c b/lib/libzfs/libzfs_pool.c
index 2f9ccbc2a..7f01143d5 100644
--- a/lib/libzfs/libzfs_pool.c
+++ b/lib/libzfs/libzfs_pool.c
@@ -5224,6 +5224,8 @@ zpool_get_vdev_prop_value(nvlist_t *nvprop, vdev_prop_t prop, char *prop_name,
case VDEV_PROP_CHECKSUM_T:
case VDEV_PROP_IO_N:
case VDEV_PROP_IO_T:
+ case VDEV_PROP_SLOW_IO_N:
+ case VDEV_PROP_SLOW_IO_T:
if (intval == UINT64_MAX) {
(void) strlcpy(buf, "-", len);
} else {