# Custom by-path mapping for large JBOD configurations
#
# Example Config:
# Sun x4550 for RHEL5
#
# Channel A: PCI Bus 2
a1 pci-0000:02:00.0-sas-0x50062b0000000001:1:0-0xd6807184d601e192:0
a2 pci-0000:02:00.0-sas-0x50062b0000000002:1:1-0xd4905378e6e3d592:1
a3 pci-0000:02:00.0-sas-0x50062b0000000003:1:2-0xd3827673d806d392:2
a4 pci-0000:02:00.0-sas-0x50062b0000000004:1:3-0xd6805385d6e3e192:3
a5 pci-0000:02:00.0-sas-0x50062b0000000005:1:4-0xd680655bd6f5b792:4
a6 pci-0000:02:00.0-sas-0x50062b0000000006:1:5-0x7a967598ec06d091:5
a7 pci-0000:02:00.0-sas-0x50062b0000000007:1:6-0xd3826c60d8fcbf92:6
a8 pci-0000:02:00.0-sas-0x50062b0000000008:1:7-0xd6805271d6e2cd92:7
# Channel B: PCI Bus 3
b1 pci-0000:03:00.0-sas-0x50062b0000000002:1:0-0xd680685fd6f8bb92:0
b2 pci-0000:03:00.0-sas-0x50062b0000000003:1:1-0xd58c706de200cb92:1
b3 pci-0000:03:00.0-sas-0x50062b0000000004:1:2-0xd5897480df04de92:2
b4 pci-0000:03:00.0-sas-0x50062b0000000005:1:3-0xd6805764d6e7c092:3
b5 pci-0000:03:00.0-sas-0x50062b0000000006:1:4-0xd6806a6dd6fac992:4
b6 pci-0000:03:00.0-sas-0x50062b0000000007:1:5-0xd58c6b84e2fbe192:5
b7 pci-0000:03:00.0-sas-0x50062b0000000008:1:6-0xd58a576ee0e7cb92:6
b8 pci-0000:03:00.0-sas-0x50062b0000000009:1:7-0xd5877871dd08cf92:7
# Channel C: PCI Bus 4
c1 pci-0000:04:00.0-sas-0x50062b0000000003:1:0-0xd6806678d6f6d492:0
c2 pci-0000:04:00.0-sas-0x50062b0000000004:1:1-0xd680696fd6f9cb92:1
c3 pci-0000:04:00.0-sas-0x50062b0000000005:1:2-0xd3827182d801e292:2
c4 pci-0000:04:00.0-sas-0x50062b0000000006:1:3-0xd680666fd6f6cb92:3
c5 pci-0000:04:00.0-sas-0x50062b0000000007:1:4-0xd6806970d6f9cc92:4
c6 pci-0000:04:00.0-sas-0x50062b0000000008:1:5-0xd6806b62d6fbbe92:5
c7 pci-0000:04:00.0-sas-0x50062b0000000009:1:6-0xd58a5760e0e7bd92:6
c8 pci-0000:04:00.0-sas-0x50062b000000000a:1:7-0xd680717fd601dc92:7
# Channel D: PCI Bus 41
d1 pci-0000:41:00.0-sas-0x50062b0000000004:1:0-0xd6806572d6f5ce92:0
d2 pci-0000:41:00.0-sas-0x50062b0000000005:1:1-0xd6806983d6f9df92:1
d3 pci-0000:41:00.0-sas-0x50062b0000000006:1:2-0xd3826c69d8fcc892:2
d4 pci-0000:41:00.0-sas-0x50062b0000000007:1:3-0xd680725fd602bc92:3
d5 pci-0000:41:00.0-sas-0x50062b0000000008:1:4-0xd6806971d6f9cd92:4
d6 pci-0000:41:00.0-sas-0x50062b0000000009:1:5-0xd680726dd602ca92:5
d7 pci-0000:41:00.0-sas-0x50062b000000000a:1:6-0xd3827772d807d292:6
d8 pci-0000:41:00.0-sas-0x50062b000000000b:1:7-0xd4955584ebe5e192:7
# Channel E: PCI Bus 42
e1 pci-0000:42:00.0-sas-0x50062b0000000005:1:0-0xd4925676e8e6d392:0
e2 pci-0000:42:00.0-sas-0x50062b0000000006:1:1-0xd6806b6ed6fbca92:1
e3 pci-0000:42:00.0-sas-0x50062b0000000007:1:2-0xd382765fd806bf92:2
e4 pci-0000:42:00.0-sas-0x50062b0000000008:1:3-0xd587786cdd08ca92:3
e5 pci-0000:42:00.0-sas-0x50062b0000000009:1:4-0xd66f4e5bc5deb792:4
e6 pci-0000:42:00.0-sas-0x50062b000000000a:1:5-0xd6806879d6f8d592:5
e7 pci-0000:42:00.0-sas-0x50062b000000000b:1:6-0xd5885175dee1d292:6
e8 pci-0000:42:00.0-sas-0x50062b000000000c:1:7-0xd588515fdee1bc92:7
# Channel F: PCI Bus 43
f1 pci-0000:43:00.0-sas-0x50062b0000000006:1:0-0xd66d6978c3f9d492:0
f2 pci-0000:43:00.0-sas-0x50062b0000000007:1:1-0xd6806a5cd6fab892:1
f3 pci-0000:43:00.0-sas-0x50062b0000000008:1:2-0xd6806563d6f5bf92:2
f4 pci-0000:43:00.0-sas-0x50062b0000000009:1:3-0xd6805664d6e6c092:3
f5 pci-0000:43:00.0-sas-0x50062b000000000a:1:4-0xd58c707ee200dc92:4
f6 pci-0000:43:00.0-sas-0x50062b000000000b:1:5-0xd5885781dee7de92:5
f7 pci-0000:43:00.0-sas-0x50062b000000000c:1:6-0xd3827481d804e192:6
f8 pci-0000:43:00.0-sas-0x50062b000000000d:1:7-0xd6806863d6f8bf92:7
|