aboutsummaryrefslogtreecommitdiffstats
path: root/include/sys/vdev_draid.h
Commit message (Collapse)AuthorAgeFilesLines
* Fix various typosAndrea Gelmini2021-04-021-1/+1
| | | | | | | | | | Correct an assortment of typos throughout the code base. Reviewed-by: Brian Behlendorf <[email protected]> Reviewed-by: Matthew Ahrens <[email protected]> Reviewed-by: Ryan Moeller <[email protected]> Signed-off-by: Andrea Gelmini <[email protected]> Closes #11774
* Distributed Spare (dRAID) FeatureBrian Behlendorf2020-11-131-0/+110
This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <[email protected]> Co-authored-by: Mark Maybee <[email protected]> Co-authored-by: Don Brady <[email protected]> Co-authored-by: Matthew Ahrens <[email protected]> Co-authored-by: Brian Behlendorf <[email protected]> Reviewed-by: Mark Maybee <[email protected]> Reviewed-by: Matt Ahrens <[email protected]> Reviewed-by: Tony Hutter <[email protected]> Signed-off-by: Brian Behlendorf <[email protected]> Closes #10102