diff options
Diffstat (limited to 'cmd')
l---------[-rwxr-xr-x] | cmd/zed/zed.d/data-notify.sh | 46 | ||||
-rwxr-xr-x | cmd/zed/zed.d/io-notify.sh | 21 |
2 files changed, 16 insertions, 51 deletions
diff --git a/cmd/zed/zed.d/data-notify.sh b/cmd/zed/zed.d/data-notify.sh index 6b65c3815..900873807 100755..120000 --- a/cmd/zed/zed.d/data-notify.sh +++ b/cmd/zed/zed.d/data-notify.sh @@ -1,45 +1 @@ -#!/bin/sh -# -# Send notification in response to a DATA error. -# -# Only one notification per ZED_NOTIFY_INTERVAL_SECS will be sent for a given -# class/pool combination. This protects against spamming the recipient -# should multiple events occur together in time for the same pool. -# -# Exit codes: -# 0: notification sent -# 1: notification failed -# 2: notification not configured -# 3: notification suppressed -# 9: internal error - -[ -f "${ZED_ZEDLET_DIR}/zed.rc" ] && . "${ZED_ZEDLET_DIR}/zed.rc" -. "${ZED_ZEDLET_DIR}/zed-functions.sh" - -[ -n "${ZEVENT_POOL}" ] || exit 9 -[ -n "${ZEVENT_SUBCLASS}" ] || exit 9 - -if [ "${ZEVENT_SUBCLASS}" != "data" ]; then \ - zed_log_err "unsupported event class \"${ZEVENT_SUBCLASS}\"" - exit 9 -fi - -zed_rate_limit "${ZEVENT_POOL};${ZEVENT_SUBCLASS};notify" || exit 3 - -umask 077 -note_subject="ZFS ${ZEVENT_SUBCLASS} error for ${ZEVENT_POOL} on $(hostname)" -note_pathname="${TMPDIR:="/tmp"}/$(basename -- "$0").${ZEVENT_EID}.$$" -{ - echo "ZFS has detected a ${ZEVENT_SUBCLASS} error:" - echo - echo " eid: ${ZEVENT_EID}" - echo " class: ${ZEVENT_SUBCLASS}" - echo " host: $(hostname)" - echo " time: ${ZEVENT_TIME_STRING}" - echo " pool: ${ZEVENT_POOL}" - -} > "${note_pathname}" - -zed_notify "${note_subject}" "${note_pathname}"; rv=$? -rm -f "${note_pathname}" -exit "${rv}" +io-notify.sh
\ No newline at end of file diff --git a/cmd/zed/zed.d/io-notify.sh b/cmd/zed/zed.d/io-notify.sh index 46b066945..3ce918ad7 100755 --- a/cmd/zed/zed.d/io-notify.sh +++ b/cmd/zed/zed.d/io-notify.sh @@ -1,10 +1,10 @@ #!/bin/sh # -# Send notification in response to a CHECKSUM or IO error. +# Send notification in response to a CHECKSUM, DATA, or IO error. # # Only one notification per ZED_NOTIFY_INTERVAL_SECS will be sent for a given -# class/pool/vdev combination. This protects against spamming the recipient -# should multiple events occur together in time for the same pool/device. +# class/pool/[vdev] combination. This protects against spamming the recipient +# should multiple events occur together in time for the same pool/[vdev]. # # Exit codes: # 0: notification sent @@ -18,16 +18,16 @@ [ -n "${ZEVENT_POOL}" ] || exit 9 [ -n "${ZEVENT_SUBCLASS}" ] || exit 9 -[ -n "${ZEVENT_VDEV_GUID}" ] || exit 9 if [ "${ZEVENT_SUBCLASS}" != "checksum" ] \ + && [ "${ZEVENT_SUBCLASS}" != "data" ] \ && [ "${ZEVENT_SUBCLASS}" != "io" ]; then zed_log_err "unsupported event class \"${ZEVENT_SUBCLASS}\"" exit 9 fi -zed_rate_limit "${ZEVENT_POOL};${ZEVENT_VDEV_GUID};${ZEVENT_SUBCLASS};notify" \ - || exit 3 +rate_limit_tag="${ZEVENT_POOL};${ZEVENT_VDEV_GUID:-0};${ZEVENT_SUBCLASS};notify" +zed_rate_limit "${rate_limit_tag}" || exit 3 umask 077 note_subject="ZFS ${ZEVENT_SUBCLASS} error for ${ZEVENT_POOL} on $(hostname)" @@ -46,6 +46,15 @@ note_pathname="${TMPDIR:="/tmp"}/$(basename -- "$0").${ZEVENT_EID}.$$" [ -n "${ZEVENT_VDEV_PATH}" ] && echo " vpath: ${ZEVENT_VDEV_PATH}" [ -n "${ZEVENT_VDEV_GUID}" ] && echo " vguid: ${ZEVENT_VDEV_GUID}" + [ -n "${ZEVENT_VDEV_CKSUM_ERRORS}" ] \ + && echo " cksum: ${ZEVENT_VDEV_CKSUM_ERRORS}" + + [ -n "${ZEVENT_VDEV_READ_ERRORS}" ] \ + && echo " read: ${ZEVENT_VDEV_READ_ERRORS}" + + [ -n "${ZEVENT_VDEV_WRITE_ERRORS}" ] \ + && echo " write: ${ZEVENT_VDEV_WRITE_ERRORS}" + echo " pool: ${ZEVENT_POOL}" } > "${note_pathname}" |