Distributed Spare (dRAID) Feature
This patch adds a new top-level vdev type called dRAID, which stands
for Distributed parity RAID. This pool configuration allows all dRAID
vdevs to participate when rebuilding to a distributed hot spare device.
This can substantially reduce the total time required to restore full
parity to pool with a failed device.
A dRAID pool can be created using the new top-level `draid` type.
Like `raidz`, the desired redundancy is specified after the type:
`draid[1,2,3]`. No additional information is required to create the
pool and reasonable default values will be chosen based on the number
of child vdevs in the dRAID vdev.
zpool create <pool> draid[1,2,3] <vdevs...>
Unlike raidz, additional optional dRAID configuration values can be
provided as part of the draid type as colon separated values. This
allows administrators to fully specify a layout for either performance
or capacity reasons. The supported options include:
zpool create <pool> \
draid[<parity>][:<data>d][:<children>c][:<spares>s] \
<vdevs...>
- draid[parity] - Parity level (default 1)
- draid[:<data>d] - Data devices per group (default 8)
- draid[:<children>c] - Expected number of child vdevs
- draid[:<spares>s] - Distributed hot spares (default 0)
Abbreviated example `zpool status` output for a 68 disk dRAID pool
with two distributed spares using special allocation classes.
```
pool: tank
state: ONLINE
config:
NAME STATE READ WRITE CKSUM
slag7 ONLINE 0 0 0
draid2:8d:68c:2s-0 ONLINE 0 0 0
L0 ONLINE 0 0 0
L1 ONLINE 0 0 0
...
U25 ONLINE 0 0 0
U26 ONLINE 0 0 0
spare-53 ONLINE 0 0 0
U27 ONLINE 0 0 0
draid2-0-0 ONLINE 0 0 0
U28 ONLINE 0 0 0
U29 ONLINE 0 0 0
...
U42 ONLINE 0 0 0
U43 ONLINE 0 0 0
special
mirror-1 ONLINE 0 0 0
L5 ONLINE 0 0 0
U5 ONLINE 0 0 0
mirror-2 ONLINE 0 0 0
L6 ONLINE 0 0 0
U6 ONLINE 0 0 0
spares
draid2-0-0 INUSE currently in use
draid2-0-1 AVAIL
```
When adding test coverage for the new dRAID vdev type the following
options were added to the ztest command. These options are leverages
by zloop.sh to test a wide range of dRAID configurations.
-K draid|raidz|random - kind of RAID to test
-D <value> - dRAID data drives per group
-S <value> - dRAID distributed hot spares
-R <value> - RAID parity (raidz or dRAID)
The zpool_create, zpool_import, redundancy, replacement and fault
test groups have all been updated provide test coverage for the
dRAID feature.
Co-authored-by: Isaac Huang <[email protected]>
Co-authored-by: Mark Maybee <[email protected]>
Co-authored-by: Don Brady <[email protected]>
Co-authored-by: Matthew Ahrens <[email protected]>
Co-authored-by: Brian Behlendorf <[email protected]>
Reviewed-by: Mark Maybee <[email protected]>
Reviewed-by: Matt Ahrens <[email protected]>
Reviewed-by: Tony Hutter <[email protected]>
Signed-off-by: Brian Behlendorf <[email protected]>
Closes #10102
Diffstat (limited to 'module/zfs/vdev_queue.c')
-rw-r--r-- | module/zfs/vdev_queue.c | 7 |
1 files changed, 7 insertions, 0 deletions
diff --git a/module/zfs/vdev_queue.c b/module/zfs/vdev_queue.c index a8ef3d747..45d92819d 100644 --- a/module/zfs/vdev_queue.c +++ b/module/zfs/vdev_queue.c @@ -593,6 +593,13 @@ vdev_queue_aggregate(vdev_queue_t *vq, zio_t *zio) if (zio->io_type == ZIO_TYPE_TRIM && !zfs_vdev_aggregate_trim) return (NULL); + /* + * I/Os to distributed spares are directly dispatched to the dRAID + * leaf vdevs for aggregation. See the comment at the end of the + * zio_vdev_io_start() function. + */ + ASSERT(vq->vq_vdev->vdev_ops != &vdev_draid_spare_ops); + first = last = zio; if (zio->io_type == ZIO_TYPE_READ) |