diff options
author | Brian Behlendorf <[email protected]> | 2020-11-13 13:51:51 -0800 |
---|---|---|
committer | GitHub <[email protected]> | 2020-11-13 13:51:51 -0800 |
commit | b2255edcc0099e62ad46a3dd9d64537663c6aee3 (patch) | |
tree | 6cfe0d0fd30fb451396551a991d50f4bdc0cf353 /module/zcommon/zfeature_common.c | |
parent | a724db03740133c46b9a577b41a6f7221acd3e1f (diff) |
Distributed Spare (dRAID) Feature
This patch adds a new top-level vdev type called dRAID, which stands
for Distributed parity RAID. This pool configuration allows all dRAID
vdevs to participate when rebuilding to a distributed hot spare device.
This can substantially reduce the total time required to restore full
parity to pool with a failed device.
A dRAID pool can be created using the new top-level `draid` type.
Like `raidz`, the desired redundancy is specified after the type:
`draid[1,2,3]`. No additional information is required to create the
pool and reasonable default values will be chosen based on the number
of child vdevs in the dRAID vdev.
zpool create <pool> draid[1,2,3] <vdevs...>
Unlike raidz, additional optional dRAID configuration values can be
provided as part of the draid type as colon separated values. This
allows administrators to fully specify a layout for either performance
or capacity reasons. The supported options include:
zpool create <pool> \
draid[<parity>][:<data>d][:<children>c][:<spares>s] \
<vdevs...>
- draid[parity] - Parity level (default 1)
- draid[:<data>d] - Data devices per group (default 8)
- draid[:<children>c] - Expected number of child vdevs
- draid[:<spares>s] - Distributed hot spares (default 0)
Abbreviated example `zpool status` output for a 68 disk dRAID pool
with two distributed spares using special allocation classes.
```
pool: tank
state: ONLINE
config:
NAME STATE READ WRITE CKSUM
slag7 ONLINE 0 0 0
draid2:8d:68c:2s-0 ONLINE 0 0 0
L0 ONLINE 0 0 0
L1 ONLINE 0 0 0
...
U25 ONLINE 0 0 0
U26 ONLINE 0 0 0
spare-53 ONLINE 0 0 0
U27 ONLINE 0 0 0
draid2-0-0 ONLINE 0 0 0
U28 ONLINE 0 0 0
U29 ONLINE 0 0 0
...
U42 ONLINE 0 0 0
U43 ONLINE 0 0 0
special
mirror-1 ONLINE 0 0 0
L5 ONLINE 0 0 0
U5 ONLINE 0 0 0
mirror-2 ONLINE 0 0 0
L6 ONLINE 0 0 0
U6 ONLINE 0 0 0
spares
draid2-0-0 INUSE currently in use
draid2-0-1 AVAIL
```
When adding test coverage for the new dRAID vdev type the following
options were added to the ztest command. These options are leverages
by zloop.sh to test a wide range of dRAID configurations.
-K draid|raidz|random - kind of RAID to test
-D <value> - dRAID data drives per group
-S <value> - dRAID distributed hot spares
-R <value> - RAID parity (raidz or dRAID)
The zpool_create, zpool_import, redundancy, replacement and fault
test groups have all been updated provide test coverage for the
dRAID feature.
Co-authored-by: Isaac Huang <[email protected]>
Co-authored-by: Mark Maybee <[email protected]>
Co-authored-by: Don Brady <[email protected]>
Co-authored-by: Matthew Ahrens <[email protected]>
Co-authored-by: Brian Behlendorf <[email protected]>
Reviewed-by: Mark Maybee <[email protected]>
Reviewed-by: Matt Ahrens <[email protected]>
Reviewed-by: Tony Hutter <[email protected]>
Signed-off-by: Brian Behlendorf <[email protected]>
Closes #10102
Diffstat (limited to 'module/zcommon/zfeature_common.c')
-rw-r--r-- | module/zcommon/zfeature_common.c | 6 |
1 files changed, 5 insertions, 1 deletions
diff --git a/module/zcommon/zfeature_common.c b/module/zcommon/zfeature_common.c index 97ddacbab..599791d49 100644 --- a/module/zcommon/zfeature_common.c +++ b/module/zcommon/zfeature_common.c @@ -576,7 +576,7 @@ zpool_feature_init(void) zfeature_register(SPA_FEATURE_DEVICE_REBUILD, "org.openzfs:device_rebuild", "device_rebuild", - "Support for sequential device rebuilds", + "Support for sequential mirror/dRAID device rebuilds", ZFEATURE_FLAG_READONLY_COMPAT, ZFEATURE_TYPE_BOOLEAN, NULL); { @@ -589,6 +589,10 @@ zpool_feature_init(void) "zstd compression algorithm support.", ZFEATURE_FLAG_PER_DATASET, ZFEATURE_TYPE_BOOLEAN, zstd_deps); } + + zfeature_register(SPA_FEATURE_DRAID, + "org.openzfs:draid", "draid", "Support for distributed parity RAID", + ZFEATURE_FLAG_MOS, ZFEATURE_TYPE_BOOLEAN, NULL); } #if defined(_KERNEL) |