summaryrefslogtreecommitdiffstats
path: root/src/gallium/auxiliary/util/u_rect.c
diff options
context:
space:
mode:
authorRobert Ellison <[email protected]>2008-12-18 09:46:53 -0700
committerRobert Ellison <[email protected]>2008-12-18 10:22:33 -0700
commit5ccef84c018c5e99bf4b8cffb5ba1bb66bf40cc4 (patch)
tree6b7cdf73355c32fff2163e62d6a1889c9e5e6568 /src/gallium/auxiliary/util/u_rect.c
parent2389c055ed4c26ba5f3979c4a7871a333725dd88 (diff)
Gallium: fix for conform test
The following construction in util_surface_copy() in gallium/auxiliary/util/u_rect.c, introduced in commit d177c9ddda2c452cf7d6696d89cf4458ef986f98, incorrectly inverts the Y coordinate in the last parameter to pipe_copy_rect(). /* If do_flip, invert src_y position and pass negative src stride */ pipe_copy_rect(dst_map, &dst->block, dst->stride, dst_x, dst_y, w, h, src_map, do_flip ? -(int) src->stride : src->stride, src_x, do_flip ? w - src_y : src_y); The intention is to start at the last Y coordinate line and move backwards, in the case of a flip; in that case, the correct calculation is "src_y + h - 1", not "w - src_y". This fixes a Gallium assertion failure in the conformance tests: u_rect.c:65:pipe_copy_rect: Assertion `src_y >= 0' failed. debug_get_bool_option: GALLIUM_ABORT_ON_ASSERT = TRUE Trace/breakpoint trap
Diffstat (limited to 'src/gallium/auxiliary/util/u_rect.c')
-rw-r--r--src/gallium/auxiliary/util/u_rect.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/src/gallium/auxiliary/util/u_rect.c b/src/gallium/auxiliary/util/u_rect.c
index 30f32413d79..fe81a685be1 100644
--- a/src/gallium/auxiliary/util/u_rect.c
+++ b/src/gallium/auxiliary/util/u_rect.c
@@ -223,7 +223,7 @@ util_surface_copy(struct pipe_context *pipe,
src_map,
do_flip ? -(int) src->stride : src->stride,
src_x,
- do_flip ? w - src_y : src_y);
+ do_flip ? src_y + h - 1 : src_y);
}
pipe->screen->surface_unmap(pipe->screen, src);